200A Power supply

Power supply rectification technology:

Plating power supply frequency is a direct current equipment of changing industry frequency alternating voltage into different voltage, frequency and waveform. In the thyristor rectifier main application of “rectification” technology, while in the high frequency switching mode power supply applying both “rectification” technology and “inverter” technology.

Plating Power supply mainly consisted of main circuit and control circuit.

Power supply definition:

Changing different voltage, frequency and waveform.
Power supply components: Main circuit and control circuit.
Power Frequency: 50Hz/60Hz.
Application: zinc plating, anodizing, chrome plating, copper plating, and other nonferrous metals plating.
Alternatives to silicon-controlled rectifier and oil dip power supply.

200A Power supply

200A Power supply

Power supply main circuit includes main transformer, power rectifier components and some other testing, protection devices. Power supply main transformer function is to reducing AC current/voltage to the plating technical process required voltage value. Thyristor rectifier uses frequency (50Hz/60Hz) transformer, while high-frequency switching power supplies using high frequency (10 ~ 50kHz) transformer. Detection devices include voltage meter, current transformers. Protection device is mainly used for power rectification components over-current protection. The control circuit includes a thyristor or IGBT, trigger control circuit, power soft-start circuit, over-current, over-voltage protection circuit, power phase protection circuit.

Power supply specification and parameter:

Power supply Input voltage Single phase 220V AC, 3 phase 380V/415V/440V 50-60Hz
Output voltage 6V/12V/15V/18V/24V/36V/48V optional or according to customers’ request
Output current 0-200A (Random optional)
Voltage stability ≤1%
Current stability ≤1%
Ripple factor 1%-2%
Efficiency ≥90%
 Stabilization mode Current stabilization/Voltage stabilization (Switchable easily)
Adjustment range Voltage/Current from 0-100% continuously adjustable within rated range
Cooling system Air cooling/Water cooling/Oil cooling
Control method Manual/PLC
Display contents Voltage meter/Current meter/Working/Over temp/Error, etc..
Protection method Input over voltage/Under voltage/Over current/Output short/Over heating self protection etc..
Operating temperature -20-50℃
Ambient temperature -30-65℃
Ambient humidity ≤90%
Working loading Full capacity operation, more than 1,000 meters above sea level, reduced load operation

Power supply Packing details:

TypeLength (mm)Width (mm)Height (mm)Weight (kg)
50A/12V3503501508
100A/12V42035015010.5
200A/12V45045020018
300A/12V50050022021
500A/12V50050020025
1000A/12V55050028038
1500A/12V60050075060
2000A/12V60050085088
3000A/12V650700850140
4000A/12V6507001100190
5000A/12V7007001450230
6000A/12V7007001700300